主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

Fire Science and Technology ›› 2021, Vol. 40 ›› Issue (2): 188-193.

Previous Articles     Next Articles

Influence of slope on the fire smoke spread of trains staying in the subway tunnel

LIU Hui-qiang, LI Yan-feng, LI Yun-fei, FAN Xian-lai, ZHAO Shou-chong   

  1. Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
  • Online:2021-02-15 Published:2021-02-15

Abstract:

A multi- scale simulation method coupled with threedimensional field simulation and one-dimensional network simulation was used to study the natural propagation of smoke when the train is on fire at the middle and the fans in adjacent stations are closed. The slopes of the long subway interval tunnels are 0‰ , 12‰ , 21‰ and 30‰ . The influence of slope on smoke diffusion and control in tunnel fire was analyzed. Comprehensive analysis on factors such as temperature, CO concentration and visibility was carried out, the danger of tunnel environment changes over time in the initial stage of the fire was studied and the available safe evacuation time for personnel was obtained. When the train is blocked in the gradient section of the section tunnel and the gradient reaches 30‰ , there is a step change of CO concentration in the tunnel because of the backflow phenomenon. 

Key words: subway, interval tunnel, slope, smoke propagation, multi-scale simulation