主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

Fire Science and Technology ›› 2024, Vol. 43 ›› Issue (11): 1549-1554.

Previous Articles     Next Articles

Analysis of flow characteristics of pipe network of perfluorophenone fire extinguishing system based on theoretical calculation

LiuXin1,2,3, Wu Hongyou1,2,3, Gao Yunsheng1,2,3, Song Wenqi1,2,3   

  1. (1. Tianjin Fire Research Institute of Emergency Management Department, Tianjin 300381, China; 2. Key Laboratory of Fire Protection Technology for Industry and Public Building, Ministry of Emergency Management, Tianjin 300381, China; 3. Tianjin Key Laboratory of Fire Safety Technology, Tianjin 300381, China)
  • Received:2024-02-18 Revised:2024-03-27 Online:2024-11-15 Published:2024-11-15

Abstract: The flow characteristics of the pipe network of the perfluorophenone fire extinguishing system have an important influence on the time and state of the fire extinguishing agent injection, which in turn affects the fire extinguishing efficiency of the whole system. In this paper, a fluid mechanics model has been adopted to calculate the pipe flow of the perfluorohexanone fire extinguishing system. Different stages of the pipe flow process have been analyzed qualitatively, and the important characteristic pa⁃rameters such as pipe pressure, flow rate and agent discharge time in each stage have been studied quantitatively. The study revealed the pipe flow characteristics of the perfluorohexanone fire extinguishing system, providing a theoretical basis for further engineering design and calculation of the system pipe network.

Key words: perfluorophenone, pipe network design, theoretical calculation, flow characteristics