Investigation and simulation experiment analysis of an electric explosion furnace fire

LIU Xing-hua   

  1. (Guangdong Fire and Rescue Brigade, Guangdong Guangzhou 510640, China)
  • Online:2022-08-15 Published:2022-08-15

Abstract: In order to restore and find the mechanism of an electric fryer fire, in the process of investigation, through the flash point of oil test, electric fryer dry burning test, temperature sensing device failure test, temperature sensing probe covered test, observe the change of oil temperature in electric fryer. Finally, it is concluded that the oil temperature cannot be accurately measured by the temperature sensing device under the condition that the temperature control device fails or the oil temperature sensing probe is wrapped, and the oil can be burned by continuous heating of the heating tube. The mechanism of fire in electric fryer during frying is further analyzed, which provides some ideas for fire investigation and fire prevention and control.

Key words: electric explosion furnace, fire investigation, temperature sensing failure