主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

Fire Science and Technology ›› 2021, Vol. 40 ›› Issue (10): 1489-1493.

Previous Articles     Next Articles

Mechanism research on fire inhibition using water spraying device installed on LNG tank vehicles

ZHOU Dan1, YE Cheng1, ZHANG Bo-jun1, WANG Zhi-rong2   

  1. 1. Nanjing Boiler and Pressure Vessel Inspection Institute, Jiangsu Nanjing 210019, China; 2. College of Safety Science and Engineering, Nanjing Tech University, Jiangsu Nanjing 210000, China)
  • Online:2021-10-15 Published:2021-10-15

Abstract: : Taking LNG tank vehicle operation box as research object, by buliding unsteady numerical model of watermist inhibiting combustion after leakage in confined space, effects and mechanisms of different nozzle heights, intervals and spraying angle on fire inhibition were studied. The results showed that with the increase of nozzle height, intervals and spraying angle, the relative humidity in the control cabinet first increases and then decreases. The higher the nozzle height, the faster the initial rise rate of evaporation rate and average humidity, the higher the peak value of evaporation rate, and faster the decline rate after reaching the peak value. Reasonable arrangement of water spraying device can significantly accelerate the flow rate of the flow field, uniform flow field distribution, prevent leakage gas accumulation, increase average humidity, and prevent fire and explosion.

Key words: fire protection, LNG tank vehicles, leakage, emergency disposal, water spraying