主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

Fire Science and Technology ›› 2021, Vol. 40 ›› Issue (9): 1327-1331.

Previous Articles     Next Articles

Research on the evacuation safety of Yellow River road-rail tunnel

ZHAO Shi-chao1,ZHANG Liang-liang2, JIANG Xue-peng3,WANG Mei-na3   

  1. 1. Jinan City Construction Group, Shandong Jinan 250000, China; 2. Tunnel Design Institute, China Railway Siyuan Survey and Design Group Co., Ltd., Hubei Wuhan 430081,China; 3. School of Resource and Environmental Engineering, Wuhan University of Science and Technology, Hubei Wuhan 430081, China
  • Online:2021-09-15 Published:2021-09-15

Abstract: Taking the Jinan Yellow River road-rail tunnel as the research object, the impact of the distance between the vertical evacuation stairs and the horizontal evacuation door on the evacuation time of the people in the case of road tunnels and rail transit fires was analyzed, and the necessary evacuation time was obtained. The results show that when the distance between any two evacuation stairs is 60 m and 75 m, it meets the requirements for safe evacuation. When a fire occurs in rail transit, the available safe evacuation time is 2 700 s under effective ventilation. When the distance between any two evacuation doors is 150 m and 300 m, it meets safety evacuation requirements. Considering safety and operating costs, it is recommended to set the distance between the evacuation stairs as 75 m and the distance between the evacuation doors of the lower storey as 300 m.

Key words: tunnel fire, road-rail tunnel, evacuation, numerical simulation