主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

Fire Science and Technology ›› 2020, Vol. 39 ›› Issue (3): 301-304.

Previous Articles     Next Articles

Study on critical time of train fire ventilation in metro section tunnel

JIANG Xue-peng1,2,3,JING An1,2   

  1. 1. School of Resource and Environmental Engineering,Wuhan University of Science and Technology,Hubei Wuhan 430081, China; 2. Fire Safety Technology Institute,Wuhan University of Science and Technology, Hubei Wuhan 430081,China; 3. Hubei Provincial Industrial Safety Engineering Technology Research Center,Hubei Wuhan 430081,China
  • Online:2020-03-15 Published:2020-03-15

Abstract: In order to get the critical time of fire ventilation for metro trains, the required safe evacuation time is obtained by using the
formula of safety evacuation time for metro accidents, and compared with the available safe evacuation time obtained by numerical simulation of fire. The results show that when the fire happens in the middle of the subway train stopping at section, and the HRR is 5,7.5,10 MW, respectively, the longitudinal ventilation and smoke exhaust system should be activated to organize the evacuation of personnel in the upwind direction; when the power of HRR is 5 MW and the wind speed of longitudinal ventilation is 2.0 m/s, the safe evacuation of personnel can be guaranteed by starting ventilation in
150~180 s; when the HRR is 7.5,10 MW, and the longitudinal ventilation wind speed is 2.4 or 2.6 m/s respectively, ventilation can be started at 120~180 s to ensure the safe evacuation of personnel.Therefore, the critical time of ventilation is 120 s when the fan changes from static state to accident state; the critical time of ventilation from operation state to accident condition is 90 s.