主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

消防科学与技术 ›› 2021, Vol. 40 ›› Issue (4): 499-503.

• • 上一篇    下一篇

钢筋混凝土保护钢管混凝土短柱火灾后力学性能研究

项凯,韩伟平,潘雁翀,赵璧   

  1. 应急管理部天津消防研究所,天津300381
  • 出版日期:2021-04-15 发布日期:2021-04-15
  • 作者简介:项凯(1980-),男,辽宁瓦房店人,应急管理部天津消防研究所副研究员,主要从事工程结构抗火研究,天津市南开区卫津南路110 号,300381。
  • 基金资助:
    国家重点研发计划(2018YFC0807600);国家自然科学基金项目(51778018);应急管理部天津消防研究所基科费项目(2020SJ07)

Study on mechanical properties of reinforced concrete protected concrete filled steel tubular stub columns after fire

XIANG Kai, HAN Wei-ping, PAN Yan-chong, ZHAO Bi   

  1. Tianjin Fire Science and Technology Research Institute of MEM, Tianjin 300381, China
  • Online:2021-04-15 Published:2021-04-15

摘要: 采用试验验证的有限元模型分析了主要影响因素。提出了钢筋混凝土保护钢管混凝土短柱火灾后轴压承载力和轴向刚度的计算方法。研究结果表明:(1)钢筋混凝土保护钢管混凝土短柱火灾后的轴压承载力和轴向刚度明显下降,随着受火时间的增加,轴向刚度的降低幅度更大;(2)截面核心面积比是火灾后轴压承载力降幅变化的主要影响因素。截面核心面积比和含管率是火灾后轴向刚度降幅变化的主要影响因素;(3)提出的简化计算方法可以预测钢筋混凝土保护钢管混凝土短柱火灾后的轴压承载力和轴向刚度。

关键词: 火灾, 钢管混凝土柱, 轴压承载力, 轴向刚度, 简化计算方法

Abstract:  In order to study mechanical properties of reinforced concrete protected concrete filled steel tubular (CFST) columns after fire, the finite element method was used to analyze the reduction amplitude of axial bearing capacity and axial stiffness. The axial bearing capacity and axial stiffness parametric analysis is discussed with experimental verified finite element model. The computing method of the residual axial bearing capacity and axial stiffness are obtained. The results show that: (1) Axial bearing capacity and axial stiffness of reinforced concrete protected CFST stub columns after fire decrease significantly. With the increase of heating time, reduction of axial stiffness is higher than that of axial bearing capacity; (2) Sectional core area ratio has significant influence on the reduced level of axial bearing capacity for reinforced concrete protected CFST stub columns after fire. Sectional core area ratio and steel tube ratio have significant influence on the reduced level of axial stiffness for reinforced concrete protected CFST stub columns after fire; (3) The simplified calculating method is able to predict the residual axial bearing capacity and axial stiffness of reinforced concrete protected CFST stub columns after fire. 

Key words: fire, concrete filled steel tubular column, axial bearing capacity, axial stiffness, simplified calculation method